KYN28-12 metal armored removable high voltage switchgear
Name

KYN28-12 metal armored removable high voltage switchgear

Summary information
The device is an indoor metal armored central switch device (hereinafter referred to as a switch device).
没有此类产品
Description

Overview

The device is an indoor metal armored central switch device (hereinafter referred to as a switch device). It is a complete power distribution device of 3~12 kV, three-phase AC 50Hz single bus and single bus segmentation system. It is mainly used for power transmission, power transmission and large-scale high-voltage motor starting in power plants, small and medium-sized generators, power distribution, industrial and mining enterprises, and secondary substations of power systems. Implement control and protection. The switchgear meets the requirements of DL/T40497, Ec298GB3906, etc. It has the function of preventing the push-pull circuit breaker with load, preventing the mis-separation of the circuit breaker and preventing the grounding switch from closing the circuit breaker when it is in the closed position, preventing accidental entry into the live compartment, preventing The interlock function of the grounding switch when the power is turned on can be used with ABB's VD4 vacuum circuit breaker and VS1 vacuum circuit breaker. It is a power distribution device with superior performance.

 

Use of environmental conditions

1. Normal environmental conditions

a. Weekly trapped air temperature: upper limit +40C. lower limit -10 °C

b. Altitude: 1000m

c. Relative ambient humidity: daily average relative humidity is not more than 95%, monthly average relative humidity is not more than 90%

d. Earthquake intensity: no more than 8 degrees

The air around e should be free from corrosive or flammable gas, water vapor, etc.

f. No serious pollution and frequent severe vibrations. Severe conditions under severe conditions meet the requirements of the United States.

2. Special working conditions

It is negotiated between the user and the manufacturer when it is used under normal environmental conditions as specified in GB3906.

 

Model and meaning

The main technical parameters

1. Switch cabinet technical parameter table

2. VS1 and VD4 vacuum circuit breaker technical data sheet

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待